Brief Introduction
This Slit lamp camera is consisting of Micro-computer, control card, optics, printer, etc. This is an ophthalmic optical instrument for checking ocular front part and inner parts. It utilizes the principles of optical magnification and KO-ehler illumination. It can be exactly used to check diseases of eyelids, corneas, anterior chamber, sclera, iris, crystalline lens and retinas. If fixed with diffuse lens, it can expand sight scope. Its preset lens can be used to check local pathological changes of ocular fundus and other functions.
❈In order to avoid injury, prevent the product damaging and be likely to cause other dangers, please read the notes carefully.
Applicable scope: It is used to check disease of cornea, ACD, iris, and lens.
Taboo sickness: There is no taboo sickness for this instrument.
Technical Specification (Anterior Segment Photo) | |
Model |
SLM-3ER |
Microscope Type |
Galileo Parallel |
Image Capturing Way |
Canon 1300D 18Mega or D5300 with High DefinitionDSLR 24.1Mega pixels |
Synchronous Flash Illumination Compensation System |
Optional |
Coaxial Background Light System |
Yes |
Magnifications change way |
Drum Five Magnifications |
Eyepiece Magnification |
12.5x |
Total Magnifications |
6X 10X 16X 25X 40X |
Diopter Adjustment |
-5D ~ +5D |
Illumination |
Five Steps (Stepless Optional) |
Slit Width |
0-14mm Continuous |
Slit Height |
1-14mm Continuous |
Slit Angle |
0°-180° Adjustable |
Slit Inclination Angle |
5° 10° 15° 20° |
Light Spot Diameter |
0.2mm,1mm,2mm,5mm,10mm,14mm |
Filter |
Heat Absorption;Grey;Redfree;Cobalt Blue |
Fixation |
Red LED |
Power | |
Illumination Bulb |
German Osram Halogen Tungsten Lamp |
Input Voltage |
110V/220V(±10%) |
Input Power |
300VA |
Diffuse Lens |
Yes |
Preset Lens |
Yes |
Laser Interface |
Yes |
Storage and transportation
1. To prevent the instrument from being damp, standing upside down and shaking violently. It needs to be stored in a room where the relative humidity is less than or equal to 85%, the ambient humidity is between -40 degrees and -55 degrees, the atmospheric pressure is between 700hPa and 1060 hPa, and the room is well ventilated and free of corrosive gases.
2. If the installed Slit lamp camera needs to be moved or transported in a short distance, all moving components must be locked. Please support its rear with your hands, and push or lift it carefully. If the instrument must be transported long distances, please repackage it for transportation to avoid product damage.